Product Parameters
- Pressure Ranges: from 0-75mbar up to 0-20bar differential with 10:1 turndown ratio
- Static Line Pressures: 130 bar, including one side only protection
- Accuracy: 0.1% full scale (IEC60770)
- Output Signal: 4-20mA with HART coms, 2 wire loop, linear or sqrt extraction
- Electrical Connections: Terminal clamps with M20 x 1.5 cable gland
- Pressure Connnection: 1/4-18 NPT female
- Special Features: HART communications compatible, mechanical stops for overpressure protection, 10 to 1 range turn-down, ATEX approved intrinsic safety or flame proof, linear or square root extraction signal
- Special Options: Integrated local readout display
- Media Compatibility: Stainless steel 316L pressure port and diaphragm with FKM or EPDM seals
- Dimensions: 125 x 82 x 198 mm including electronics housing
- Weight: min 3.5kg
Product Description
The XMD has a standard process configuration with kidney flange mounting arrangement and large accessible electronic housing.
Other features include ATEX intrinsic safety or flameproof, linear or square root extraction 4-20mA output, HART communications, 10 to 1 turndown ranging, LCD readout and 130 bar overpressure protection on one side.
The XMD process DP cell is designed for use in control and monitoring applications on process sites such as oil refineries, pharmaceutical plant, chemical manufacture, power stations, food processing and paper mills.
HART communications is enable as standard allowing the operator to access device information such as type, range and serial number and carry out re-ranging or re-calibration procedures via a HART compatible programming handset.
For convenient stocking of spares and rapid configuration across a number of different applications the 4-20mA output of the transmitter can be rescaled down to 1/10 of the nominal pressure range.
A 0.1% of full scale is maintained down to 1/5 of the range beyond which the accuracy will gradually decrease to a maximum of 0.25% at 1/10 of the nominal range.
The XMD HART pressure transmitter is adaptable to many different purposes on a process site.
The output can be switched to a square root extraction for use as a flow measurement device.
The negative port can be left vented to create a gauge reference process transmitter, it can be installed with an IS barrier for use in a area where an explosion caused by gas or dust is a potential hazard.
SensorsOne XMD Process Plant DP Cell Differential Pressure Transmitter
- Product Code: XMD Process Plant
- Availability: Pre-Order
-
Rp.0.00
- Ex Tax: Rp.0.00
Notice: Undefined index: button_position in /home/u7567509/public_html/system/storage/modification/catalog/view/theme/default/template/product/product.tpl on line 337
Related Products
SensorsOne DPS200 HVAC Differential Pressure Transmitter
Product Parameters Pressure Ranges: 600 Pa (6mb) to 100 kPa (1 bar) differential Accuracy: 1% FS..
Rp.0.00 Ex Tax: Rp.0.00
SensorsOne DPS Low Differential Pressure Transmitter
DPS very low differential pressure transducer is an affordable option for measuring the differential..
Rp.0.00 Ex Tax: Rp.0.00
SensorsOne DPS300 User Switchable Pressure Range, Volts or Current Output Low DP Sensor
Product Parameters Pressure Range: 100 Pa up to 1000 mb differential Output Signal: 3 wire switc..
Rp.0.00 Ex Tax: Rp.0.00
SensorsOne DPT200 Pressurised Tank Level Differential Pressure Transmitter
Product Description This dp cell transmitter is used to determine the quantity of liquid ins..
Rp.0.00 Ex Tax: Rp.0.00
SensorsOne DMD341 Compact Differential Air Pressure Sensor
Product Parameters Pressure Ranges: from 0-6mbar up to 0-1000 mbar differential including bi-dire..
Rp.0.00 Ex Tax: Rp.0.00
Tags: SensorsOne, XMD, Process, Plant, DP, Cell, Differential, Pressure, Transmitter